Poly-clip PDC-A 700 #2865
Repairs, air valves and leaking hoses.
Adjusted magnet for safety switch.
Tested manually non-opinionated
Nice condition, no remarks.

Vacuum machine Cryovac VC 14 RH #2273
Replace air distributor Replace welding tape Change the oil Fixed connectors for pinch protection Double weld + cut off

Traysealer Tecnovac Olympia 210x140mm #2342
Directed upper part. Refurbished plastic roller. Change the main switch. Adjusted circuit board for buttons. Change cover gasket. Change oil+filter in vac pump. Tool: 210x140mm

Traysealer Enterpack with Printer #2507
New potentiometer for speed control. Cleaned and adjusted air valves. Printer responds and runs but lacks ink. No vacuum, machine is used running on food grade gas. Tools: 195x150, 225x155 (oval), 230x190mm

Double chamber Henkovac A-5000 -2008 #2215
Mounted cutoff on-off Replace main power switch Renovated welding beam The machine runs with an external vacuum pump or central vacuum (pump not included, can be purchased separately) Welding beam: 80x70cm The conveyor belt is included

2005 UVA Flash 250
Test run and adjusted welding times Works well Tube dimension: 156mm Welding width: 25cm Front cup missing, sensor bridged